Boiler & Heat Exchanger Tubes

Heat Exchanger Tube

Heat exchanger and condenser tubes supplied against ASTM, ASME, EN, JIS and project specifications.

Product Overview

Tube supply for condensers and shell-and-tube equipment

Himount supplies heat exchanger tubes for condensers, shell-and-tube heat exchangers, heaters, boilers, economizers and process equipment. Orders can be routed as seamless, ERW or welded stainless tube depending on service condition, standard, material grade, OD, wall thickness, length, testing scope and documentation requirements.

A179Seamless condenser tube
A214ERW heat exchanger tube
A213Alloy and stainless route
A249Welded stainless option

Key Specifications

Product formsSeamless heat exchanger tube, ERW condenser tube, welded stainless heat exchanger tube, straight tube, U-bent tube and finned tube by project.
Primary standardsASTM A179 / ASME SA-179, ASTM A214 / ASME SA-214, ASTM A213 / ASME SA-213, ASTM A249 / ASME SA-249, EN 10216-2, EN 10216-5, EN 10217-7, JIS G3461 and JIS G3463.
Common gradesSA-179, SA-214, SA213 T11, T22, T91, TP304, TP304L, TP316, TP316L, P235GH, P265GH, 1.4301, 1.4404 and project-specified equivalent grades.
Manufacturing routeCold drawn seamless, ERW carbon steel, welded stainless, solution annealed or normalized condition, straightened, cut to length, inspected and packed by order.
Size and finishOD, wall thickness, length, straightness, end cut, surface, U-bend radius, leg length, tube sheet layout and packing are confirmed against drawing or purchase specification.
Inspection and testsDimensional inspection, chemical and mechanical tests, eddy current, hydrostatic test or pneumatic test, flattening, flaring, PMI, IGC and third-party inspection when required.
Order detailsConfirm standard edition, grade, OD, wall, length or U-bend drawing, heat treatment, testing plan, MTC level, surface, packing, quantity, delivery schedule and destination port.

Typical Applications

Where heat exchanger tube is specified

Condensers and exchangersShell-and-tube heat exchangers, condensers, coolers, evaporators and process equipment where tube material and testing define service reliability.
Boiler and energy systemsBoiler auxiliary equipment, heaters, economizers, power plant packages and energy projects requiring traceable tube standards and inspection records.
Chemical and marine serviceRefinery, petrochemical, desalination, marine and utility projects where stainless, alloy or carbon steel tubes are selected by corrosion and temperature conditions.
U-bend note

For U-bent tubes, confirm straight length before bending, bend radius, leg length tolerance, heat treatment after bending, bundle layout, protection and whether hydrotest or pneumatic test is required after bending.

Material note

Heat exchanger tubes are not quoted by shape alone. Media, temperature, pressure, corrosion allowance, tube sheet design, inspection class and local code decide whether carbon, alloy or stainless material is suitable.

International Model Search Index

Common standards, grades and RFQ terms

Standards and grade calls
ASTM A179 heat exchanger tubeASME SA-179 condenser tubeASTM A214 ERW condenser tubeASTM A213 T11 heat exchanger tubeASTM A213 T22 boiler tubeASTM A213 TP316L stainless tubeASTM A249 welded stainless tubeEN 10216-2 P235GH tubeJIS G3461 STB tube
Size and order phrases
OD x wall x lengthU-bend heat exchanger tubestraight condenser tubecold drawn seamless tubeeddy current tested tubesolution annealed stainless tubetube bundle replacement
Buyer search phrases
heat exchanger tube supplierSA179 seamless tube exporterA214 ERW condenser tubestainless heat exchanger tubeU bend tube manufacturerboiler heat exchanger tube stock

Buyer FAQ

Questions to settle before quotation

Which standards are common for heat exchanger tube?

Common references include ASTM A179 or ASME SA-179 for seamless low-carbon steel heat exchanger and condenser tubes, ASTM A214 for ERW carbon steel tubes, ASTM A213 for alloy or stainless seamless tubes, ASTM A249 for welded stainless tubes, plus EN and JIS project references.

When should seamless tube be selected?

Seamless tube is often selected when the project specification, pressure, temperature, wall thickness, drawing or inspection plan requires a seamless route. The final choice should follow the equipment design and ordered standard.

Can Himount supply U-bent heat exchanger tube?

U-bent tube can be arranged when the buyer confirms tube standard, grade, OD, wall thickness, straight length, bend radius, leg length, heat treatment after bending, testing and packing requirements.

What information is needed for a quotation?

Confirm standard, material grade, OD, wall thickness, length or U-bend drawing, end condition, surface, heat treatment, test scope, MTC requirement, packing, quantity and destination port.

Related Products

Other products in Boiler & Heat Exchanger Tubes

Send RFQ for Heat Exchanger Tube

Share standard, grade, OD, wall, straight or U-bent drawing, heat treatment, test scope, MTC, packing and destination details.

Request a Quote